Controlled Release
Controlled gasket failure releases the venting panel. Installation condition directly affects the consistency of the release pressure.
A fastener for building explosion venting systems. At the preset release condition, controlled gasket failure releases the venting panel in the designed safe direction.

TKC-01 works with the pressure-bearing structure and venting panel for wall and roof venting constructions. It provides a designed-release trigger connection; it is not an independent venting system.
Where a project needs to manage venting-panel flight risk, TKC-01 can be paired with the TKC-JS900 restraint cable as a pressure-relief-plus-restraint configuration. Layout and quantity must be determined by venting calculations and project drawings.
Controlled gasket failure releases the venting panel. Installation condition directly affects the consistency of the release pressure.
A domed waterproof gasket works with the T30 Torx self-drilling screw for a straightforward site installation configuration.
Salt spray testing ≥1000–1500 hours supports use in high-humidity, high-salinity, and industrial environments.
Fastener layout and quantity must be determined by venting design calculations and project drawings; they must not be altered arbitrarily on site.
Do not over-tighten. The gasket need only contact the panel evenly; pre-compression deformation changes its expected release behaviour.
Use material, installation, drawing, and photographic records to form traceable project documentation.

TKC-01
Share the venting design, panel construction, and project drawings. TKC can help confirm the system configuration, document list, and key site-installation controls.